In 04/2015, Chris Helmkamp, Helmkamp Marine Services, Chesapeake Beach, MD, (618) 567-6288, designed and installed a single Flo5.0 diaphragm water pressure pump, model 42755, with two y-valves that can serve as both an anchor washdown pump system and a manual bilge pump system. The macerator pump was broken and was not going to be used in the Chesapeake Bay, so the existing raw water intake valve under the starboard settee was used to bring in water for the washdown pump in the anchor locker. The pump is powerful enough to produce a strong volume of water to the anchor locker. A coiled hose was left in place in the forward bilge compartment to reach all three bilge areas, under the holding tank and under the galley sink, and even the fresh water tank under the port settee. The hose is not long enough to reach the forward water tank but I can probably attach another hose to the coiled hose to pump out the forward water tank. All bilge areas have been bone dry for several weeks. Parts and 9.5 hrs labor… $1,200. A dry bilge…priceless.
  • 003-anchor washdown-bilge pump system
    Wednesday, July 29 2015 @ 08:08 PM EDT
    0 Comments
    Views 2305
    • Currently 0.00/5
    Rating: 0.00/5 (0 votes cast)
  • 004-anchor washdown hose
    Wednesday, July 29 2015 @ 08:08 PM EDT
    0 Comments
    Views 2351
    • Currently 0.00/5
    Rating: 0.00/5 (0 votes cast)
  • 005-Supply and raw water hoses
    Wednesday, July 29 2015 @ 08:09 PM EDT
    0 Comments
    Views 2360
    • Currently 0.00/5
    Rating: 0.00/5 (0 votes cast)
  • 006-Bilge supply hose
    Wednesday, July 29 2015 @ 08:09 PM EDT
    0 Comments
    Views 2292
    • Currently 0.00/5
    Rating: 0.00/5 (0 votes cast)
  • 007-Bilge out hose
    Wednesday, July 29 2015 @ 08:09 PM EDT
    0 Comments
    Views 2536
    • Currently 0.00/5
    Rating: 0.00/5 (0 votes cast)
  • 008-hose to bilge pump
    Wednesday, July 29 2015 @ 08:10 PM EDT
    0 Comments
    Views 2332
    • Currently 0.00/5
    Rating: 0.00/5 (0 votes cast)
  • 009-hose to bilge pump
    Wednesday, July 29 2015 @ 08:10 PM EDT
    0 Comments
    Views 2975
    • Currently 0.00/5
    Rating: 0.00/5 (0 votes cast)
  • 010-raw water intake from old macerator
    Wednesday, July 29 2015 @ 08:11 PM EDT
    0 Comments
    Views 2566
    • Currently 0.00/5
    Rating: 0.00/5 (0 votes cast)
  • 011-hose coiled in forward DRY bilge
    Wednesday, July 29 2015 @ 08:13 PM EDT
    0 Comments
    Views 2554
    • Currently 0.00/5
    Rating: 0.00/5 (0 votes cast)
  • 012-middle bilge-DRY
    Wednesday, July 29 2015 @ 08:13 PM EDT
    0 Comments
    Views 2658
    • Currently 0.00/5
    Rating: 0.00/5 (0 votes cast)
  • 013-aft main bilge-DRY - clear water in shower bilge
    Wednesday, July 29 2015 @ 08:13 PM EDT
    0 Comments
    Views 2672
    • Currently 0.00/5
    Rating: 0.00/5 (0 votes cast)
  • 014-view of open compartments under starboard settee
    Wednesday, July 29 2015 @ 08:06 PM EDT
    0 Comments
    Views 2626
    • Currently 0.00/5
    Rating: 0.00/5 (0 votes cast)
Jump to
  • 1
  • 2
Album ID: 289 
Sort By